Your characteristics and limits, not ours
- Characteristics, limits, units and when a first piece is needed come from your drawing, control plan or customer. The file quotes no limits or values from any standard or customer and fills in none for you.
- A logged first piece records what was measured on that part on that date. It says nothing about the parts made after it.
- First piece and first article are not the same thing here: this log is for the routine check at a setup, tool change or shift start. For a full first article report, see the first article inspection report template.
What is in the file
- Settings: an as-of date (blank means today).
- Log, one row per characteristic: FPI ID, part number, revision (if any), line or machine, trigger, checked on, checked by, characteristic, lower limit and upper limit (yours), measured value, gauge or method, run decision, decision by, decision on, notes.
- Within your limits: Yes, No, or blank when a number is missing, worked out from your limits and the measured value. A value equal to a limit counts as within.
- A separate check column. The status does not hide it, a filled date or number is checked for the cases listed below, and a row can show several notes, joined with a semicolon.
- Counts under the log: rows logged, rows per status, rows with a check note, rows outside your limits, a line that should read 0 (rows not in any status), rows per trigger and rows per run decision. No score and no ranking.
How the status is worked out
In this order; the first match wins. Text typed in a date or number cell counts as blank:
| Status | When |
|---|---|
| Enter FPI ID | The row has an entry but no FPI ID. It still counts. |
| Enter part number, Enter line or machine | In that order. Revision is optional. |
| Enter trigger | Blank, or typed outside the list (New setup, Tool change, Shift start, Material lot change, After repair, Other). |
| Enter checked-on date, Enter checked by | Date (blank or text counts as blank), then the name. |
| Enter characteristic | Characteristic blank. |
| Enter a lower or upper limit (yours) | Neither limit is a number. One limit is enough for a one-sided limit. The limits are your own; the file fills in none. |
| Enter measured value | Blank, or text instead of a number. |
| Enter run decision | Blank, or typed outside the list (Released to run, Held, Not decided yet). |
| Run decision not made | Run decision Not decided yet. |
| Held | Run decision Held. |
| Enter decision by, Enter decision date | Released to run, name or date missing. |
| Released, a value in this FPI outside your limits | Released to run, and any row with the same FPI ID is outside your limits. |
| Released, a value in this FPI could not be checked | Released to run, and any row with the same FPI ID has no measured value or no limit, so Within your limits is blank. |
| Released, all values in your limits | Released to run, every row of this FPI ID within your limits. A value equal to a limit counts as within. |
Check column notes, each followed by "worth a check", on any row whatever its status:
- Lower limit above upper limit
- Decision date before the checked-on date
- Decision by or date filled, run decision is not Released to run or Held
- Rows of one FPI ID differ in part number or checked-on date
- Rows of one FPI ID differ in run decision
- Same FPI ID and characteristic on more than one row
- Limit or measured value not a number
- A checked-on or decision date after the as-of date
- Date not readable (text in a date cell)
- Held, nothing written in Notes
- This row is outside your limits, run decision is Released to run
Example (fictional)
Made-up parts, names, limits and dates, extract, as of Wednesday 21 October 2026 (Wed 21 Oct 2026):
| FPI ID | Part | Checked on | Characteristic | Your limits | Measured | Within your limits | Run decision | Status | Check |
|---|---|---|---|---|---|---|---|---|---|
| F-01 | BR-100 | Mon 19 Oct 2026 | Hole diameter | 8 to 8.1 | 8.04 | Yes | Released to run | Released, all values in your limits | |
| F-01 | BR-100 | Mon 19 Oct 2026 | Flange height | 12 to 12.4 | 12.2 | Yes | Released to run | Released, all values in your limits | |
| F-02 | HS-220 | Tue 20 Oct 2026 | Outer diameter | 24.95 to 25.05 | 25.08 | No | Held | Held | |
| F-02 | HS-220 | Tue 20 Oct 2026 | Length | 40 to 40.3 | 40.1 | Yes | Held | Held | |
| F-03 | CL-310 | Wed 21 Oct 2026 | Slot width | 5 to 5.2 | 5.25 | No | Released to run | Released, a value in this FPI outside your limits | This row is outside your limits, run decision is Released to run: worth a check |
| F-03 | CL-310 | Wed 21 Oct 2026 | Bend angle | 89.5 to 90.5 | 90.1 | Yes | Released to run | Released, a value in this FPI outside your limits | |
| F-04 | BR-100 | Wed 21 Oct 2026 | Hole diameter | 8 to 8.1 | 8.05 | Yes | Not decided yet | Run decision not made | |
| F-05 | HS-220 | Wed 21 Oct 2026 | Outer diameter | 24.95 to 25.05 | 25.01 | Yes | Released to run | Enter decision by | |
| CL-310 | Tue 20 Oct 2026 | Slot width | 5 to 5.2 | 5.1 | Yes | Released to run | Enter FPI ID | Decision date before the checked-on date: worth a check |
Worth a check each shift
- Runs released with a value outside your limits (status Released, a value in this FPI outside your limits).
- Held runs with nothing written in Notes, and runs with no decision yet.
- Released runs with no name or date for the decision.
Whether a first piece is good and what to do with a held run is your call. The file records it and does not judge it.
Related
- First article inspection report template
- Trial run and pilot lot log
- Gauge calibration log template
- Tool and die maintenance log (by hit count)
- Free 8D and quality tools
Advisory template, in English. Not a customer decision.